Digital / Controllers
Replacement Product: innTOUCH2 Smart Sensor
The NTRC Series Network features embedded BACnet® and ModBus communication and is available in several configurations for the most efficient monitoring and control solution. The basic unit accurately measures room temperature. Optional features include RH measurement, up/down setpoint control, a local override function, a control relay output, a fan speed switch and a digital input.The device connects to an RS-485 MS/TP or Modbus RTU network to offer a single-point solution for control of indoor air quality and comfort. Features include a back-lit LCD and user menu for easy installation, field-proven sensors and user input controls to add local setpoint, override functions and a digital input at the same network point.
The NTRC Series Network features embedded BACnet® and ModBus communication and is available in several configurations for the most efficient monitoring and control solution. The basic unit accurately measures room temperature. Optional features include RH measurement, up/down setpoint control, a local override function, a control relay output, a fan speed switch and a digital input.
The device connects to an RS-485 MS/TP or Modbus RTU network to offer a single-point solution for control of indoor air quality and comfort. Features include a back-lit LCD and user menu for easy installation, field-proven sensors and user input controls to add local setpoint, override functions and a digital input at the same network point.
The basic unit accurately measures room temperature. Optional features include RH measurement, up/down setpoint control, a local override function, a control relay output, a fan speed switch and a digital input.
The ISO 9000 family of quality management systems standards is designed to help organizations ensure that they meet the needs of customers and other stakeholders while meeting statutory and regulatory requirements related to a product or service.
The RCM compliance mark indicates that a device complies with applicable radiocommunication and electrical safety standards.
Restriction of Hazardous Substances in Electrical and Electronic Equipment
The operating voltage must meet the requirements of Safety Extra Low Voltage (SELV) to EN60730. The transformer used must be a class 2 safety transformer in compliance with EN60742 and be designed for 100% duty. It must also be sized and fused in compliance with local safety regulations.
View our distributor list
This website uses cookies to improve user experience. By using our website you consent to all cookies in accordance with our Privacy Policy.